beremiz

SVGHMI: Filter unseen geometry from inkscape CSV output.
svghmi
2021-03-25, Edouard Tisserant
1582753e409b
SVGHMI: Filter unseen geometry from inkscape CSV output.

When inkscape exports geometry form all objects, then it also includes objects from svg:defs. This makes problems when deciding if an object is part of a page, since coordinate of objects in svg:defs can eventualy be contained in a page. In the end, those objects where getting detached when leaving pages where they where found, leading for exemple to non working text on clipping when the clipped text was cloned in multiple page.
/**
* Head of code common to all C targets
**/
#include "beremiz.h"
#include <string.h>
/*
* Prototypes of functions provided by generated C softPLC
**/
void config_run__(unsigned long tick);
void config_init__(void);
/*
* Prototypes of functions provided by generated target C code
* */
long long AtomicCompareExchange64(long long*, long long, long long);
void __init_debug(void);
void __cleanup_debug(void);
/*void __retrieve_debug(void);*/
void __publish_debug(void);
/*
* Variables used by generated C softPLC and plugins
**/
IEC_TIME __CURRENT_TIME;
IEC_BOOL __DEBUG = 0;
unsigned long __tick = 0;
char *PLC_ID = NULL;
/*
* Variable generated by C softPLC and plugins
**/
extern unsigned long greatest_tick_count__;
/* Help to quit cleanly when init fail at a certain level */
static int init_level = 0;
/*
* Prototypes of functions exported by plugins
**/
%(calls_prototypes)s
/*
* Retrieve input variables, run PLC and publish output variables
**/
void __run(void)
{
__tick++;
if (greatest_tick_count__)
__tick %%= greatest_tick_count__;
%(retrieve_calls)s
/*__retrieve_debug();*/
config_run__(__tick);
__publish_debug();
%(publish_calls)s
}
/*
* Initialize variables according to PLC's default values,
* and then init plugins with that values
**/
int __init(int argc,char **argv)
{
int res = 0;
init_level = 0;
/* Effective tick time with 1ms default value */
if(!common_ticktime__)
common_ticktime__ = 1000000;
config_init__();
__init_debug();
%(init_calls)s
return res;
}
/*
* Calls plugin cleanup proc.
**/
void __cleanup(void)
{
%(cleanup_calls)s
__cleanup_debug();
}
void PLC_GetTime(IEC_TIME *CURRENT_TIME);