beremiz

27955f010b23
Fix crash if LD input contact isn't connected

Traceback (most recent call last):
File "/home/developer/WorkData/PLC/beremiz/beremiz/BeremizIDE.py", line 339, in OnMethod
obj.CTR.CallMethod('_'+meth)
File "/home/developer/WorkData/PLC/beremiz/beremiz/ProjectController.py", line 1996, in CallMethod
getattr(self, method)()
File "/home/developer/WorkData/PLC/beremiz/beremiz/ProjectController.py", line 1134, in _Build
IECGenRes = self._Generate_SoftPLC()
File "/home/developer/WorkData/PLC/beremiz/beremiz/ProjectController.py", line 746, in _Generate_SoftPLC
if self._Generate_PLC_ST():
File "/home/developer/WorkData/PLC/beremiz/beremiz/ProjectController.py", line 763, in _Generate_PLC_ST
self._getIECgeneratedcodepath())
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCControler.py", line 456, in GenerateProgram
self.ProgramChunks = GenerateCurrentProgram(self, self.Project, errors, warnings)
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCGenerator.py", line 1762, in GenerateCurrentProgram
generator.GenerateProgram()
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCGenerator.py", line 478, in GenerateProgram
self.GeneratePouProgram(pou_name)
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCGenerator.py", line 260, in GeneratePouProgram
program = pou_program.GenerateProgram(pou)
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCGenerator.py", line 1718, in GenerateProgram
self.ComputeProgram(pou)
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCGenerator.py", line 1028, in ComputeProgram
self.GenerateBlock(instance, block_infos, body, None)
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCGenerator.py", line 1144, in GenerateBlock
expression = self.ComputeExpression(body, connections, executionOrderId > 0)
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCGenerator.py", line 1373, in ComputeExpression
paths = self.GeneratePaths(connections, body, order, to_inout)
File "/home/developer/WorkData/PLC/beremiz/beremiz/PLCGenerator.py", line 1344, in GeneratePaths
elif isinstance(result[0], list):
IndexError: list index out of range


Close #70
[FileInfo]
FileName=slave.eds
FileVersion=1
FileRevision=1
EDSVersion=4.0
Description=
CreationTime=09:10AM
CreationDate=10-27-2008
CreatedBy=CANFestival
ModificationTime=09:10AM
ModificationDate=10-27-2008
ModifiedBy=CANFestival
[DeviceInfo]
VendorName=CANFestival
VendorNumber=0x00000000
ProductName=SlaveNode
ProductNumber=0x00000000
RevisionNumber=0x00000000
BaudRate_10=1
BaudRate_20=1
BaudRate_50=1
BaudRate_125=1
BaudRate_250=1
BaudRate_500=1
BaudRate_800=1
BaudRate_1000=1
SimpleBootUpMaster=0
SimpleBootUpSlave=1
Granularity=8
DynamicChannelsSupported=0
CompactPDO=0
GroupMessaging=0
NrOfRXPDO=4
NrOfTXPDO=4
LSS_Supported=0
[DummyUsage]
Dummy0001=0
Dummy0002=1
Dummy0003=1
Dummy0004=1
Dummy0005=1
Dummy0006=1
Dummy0007=1
[Comments]
Lines=0
[MandatoryObjects]
SupportedObjects=3
1=0x1000
2=0x1001
3=0x1018
[1000]
ParameterName=Device Type
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=0
PDOMapping=0
[1001]
ParameterName=Error Register
ObjectType=0x7
DataType=0x0005
AccessType=ro
DefaultValue=0
PDOMapping=1
[1018]
ParameterName=Identity
ObjectType=0x8
SubNumber=5
[1018sub0]
ParameterName=Number of Entries
ObjectType=0x7
DataType=0x0005
AccessType=ro
DefaultValue=4
PDOMapping=0
[1018sub1]
ParameterName=Vendor ID
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=0
PDOMapping=0
[1018sub2]
ParameterName=Product Code
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=0
PDOMapping=0
[1018sub3]
ParameterName=Revision Number
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=0
PDOMapping=0
[1018sub4]
ParameterName=Serial Number
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=0
PDOMapping=0
[OptionalObjects]
SupportedObjects=1
1=0x1200
[1200]
ParameterName=Server SDO Parameter
ObjectType=0x8
SubNumber=3
[1200sub0]
ParameterName=Number of Entries
ObjectType=0x7
DataType=0x0005
AccessType=ro
DefaultValue=2
PDOMapping=0
[1200sub1]
ParameterName=COB ID Client to Server (Receive SDO)
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=$NODEID+0x600
PDOMapping=0
[1200sub2]
ParameterName=COB ID Server to Client (Transmit SDO)
ObjectType=0x7
DataType=0x0007
AccessType=ro
DefaultValue=$NODEID+0x580
PDOMapping=0
[ManufacturerObjects]
SupportedObjects=2
1=0x2000
2=0x2001
[2000]
ParameterName=OutVar
ObjectType=0x7
DataType=0x0003
AccessType=rw
DefaultValue=0
PDOMapping=1
[2001]
ParameterName=InVar
ObjectType=0x7
DataType=0x0003
AccessType=rw
DefaultValue=0
PDOMapping=1