beremiz

Avoid usage of localized strings before initialization during import in many modules

This happens if import is done before i18n setup
(InstallLocalRessources()).
This affects PLCOpenEditor mostly. Beremiz IDE is free from this issue, but moving
initialization from import should make modules more robust.
Otherwise execution result depends on where and when import was done
and this is not a good thing.

Some modules (ConfigTreeNode, features, CodeFileEditor related
classes) still have this, but they are used only in Beremiz.
Most problems result in non-working internatialization.
In some cases (VariablePanel) there is backtrace, because localized
key is not found in non-localized dictionary.
<?xml version='1.0' encoding='utf-8'?>
<project xmlns="http://www.plcopen.org/xml/tc6_0201" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xhtml="http://www.w3.org/1999/xhtml" xsi:schemaLocation="http://www.plcopen.org/xml/tc6_0201">
<fileHeader companyName="Unknown" productName="Generic PLC" productVersion="1" creationDateTime="2013-01-29T14:01:00" contentDescription="This example shows logging functionality in Beremiz.&#10;Here are shown two ways of logging:&#10;- from IEC PLC program;&#10;- from python extension.&#10;"/>
<contentHeader name="Logging example" modificationDateTime="2018-08-24T13:12:45">
<coordinateInfo>
<fbd>
<scaling x="0" y="0"/>
</fbd>
<ld>
<scaling x="0" y="0"/>
</ld>
<sfc>
<scaling x="0" y="0"/>
</sfc>
</coordinateInfo>
</contentHeader>
<types>
<dataTypes/>
<pous>
<pou name="program0" pouType="program">
<interface>
<localVars>
<variable name="beat">
<type>
<BOOL/>
</type>
</variable>
<variable name="count">
<type>
<INT/>
</type>
</variable>
<variable name="LOGGER0">
<type>
<derived name="LOGGER"/>
</type>
</variable>
<variable name="lvl">
<type>
<derived name="LOGLEVEL"/>
</type>
<initialValue>
<simpleValue value="INFO"/>
</initialValue>
</variable>
<variable name="Timer">
<type>
<derived name="TOF"/>
</type>
</variable>
</localVars>
</interface>
<body>
<FBD>
<inVariable localId="2" height="30" width="170" executionOrderId="0" negated="false">
<position x="507" y="365"/>
<connectionPointOut>
<relPosition x="170" y="15"/>
</connectionPointOut>
<expression>'IEC side logging: beat #'</expression>
</inVariable>
<block localId="3" width="59" height="40" typeName="NOT" executionOrderId="0">
<position x="241" y="287"/>
<inputVariables>
<variable formalParameter="IN">
<connectionPointIn>
<relPosition x="0" y="30"/>
<connection refLocalId="14" formalParameter="Q">
<position x="241" y="317"/>
<position x="197" y="317"/>
</connection>
</connectionPointIn>
</variable>
</inputVariables>
<inOutVariables/>
<outputVariables>
<variable formalParameter="OUT">
<connectionPointOut>
<relPosition x="59" y="30"/>
</connectionPointOut>
</variable>
</outputVariables>
</block>
<inOutVariable localId="4" height="30" width="51" executionOrderId="0" negatedOut="false" negatedIn="false">
<position x="66" y="304"/>
<connectionPointIn>
<relPosition x="0" y="15"/>
<connection refLocalId="3" formalParameter="OUT">
<position x="66" y="319"/>
<position x="37" y="319"/>
<position x="37" y="390"/>
<position x="314" y="390"/>
<position x="314" y="317"/>
<position x="300" y="317"/>
</connection>
</connectionPointIn>
<connectionPointOut>
<relPosition x="51" y="15"/>
</connectionPointOut>
<expression>beat</expression>
</inOutVariable>
<block localId="5" width="68" height="98" typeName="ADD" executionOrderId="0">
<position x="463" y="403"/>
<inputVariables>
<variable formalParameter="IN1">
<connectionPointIn>
<relPosition x="0" y="39"/>
<connection refLocalId="10" formalParameter="OUT">
<position x="463" y="442"/>
<position x="452" y="442"/>
<position x="452" y="442"/>
<position x="455" y="442"/>
<position x="455" y="442"/>
<position x="445" y="442"/>
</connection>
</connectionPointIn>
</variable>
<variable formalParameter="IN2">
<connectionPointIn>
<relPosition x="0" y="78"/>
<connection refLocalId="6">
<position x="463" y="481"/>
<position x="453" y="481"/>
<position x="453" y="482"/>
<position x="454" y="482"/>
<position x="454" y="483"/>
<position x="444" y="483"/>
</connection>
</connectionPointIn>
</variable>
</inputVariables>
<inOutVariables/>
<outputVariables>
<variable formalParameter="OUT">
<connectionPointOut>
<relPosition x="68" y="39"/>
</connectionPointOut>
</variable>
</outputVariables>
</block>
<inOutVariable localId="6" height="30" width="103" executionOrderId="0" negatedOut="false" negatedIn="false">
<position x="341" y="468"/>
<connectionPointIn>
<relPosition x="0" y="15"/>
<connection refLocalId="5" formalParameter="OUT">
<position x="341" y="483"/>
<position x="320" y="483"/>
<position x="320" y="518"/>
<position x="544" y="518"/>
<position x="544" y="442"/>
<position x="531" y="442"/>
</connection>
</connectionPointIn>
<connectionPointOut>
<relPosition x="103" y="15"/>
</connectionPointOut>
<expression>count</expression>
</inOutVariable>
<block localId="8" width="67" height="144" typeName="CONCAT" executionOrderId="0">
<position x="727" y="329"/>
<inputVariables>
<variable formalParameter="IN1">
<connectionPointIn>
<relPosition x="0" y="51"/>
<connection refLocalId="2">
<position x="727" y="380"/>
<position x="677" y="380"/>
</connection>
</connectionPointIn>
</variable>
<variable formalParameter="IN2">
<connectionPointIn>
<relPosition x="0" y="113"/>
<connection refLocalId="9" formalParameter="OUT">
<position x="727" y="442"/>
<position x="680" y="442"/>
</connection>
</connectionPointIn>
</variable>
</inputVariables>
<inOutVariables/>
<outputVariables>
<variable formalParameter="OUT">
<connectionPointOut>
<relPosition x="67" y="51"/>
</connectionPointOut>
</variable>
</outputVariables>
</block>
<block localId="9" width="119" height="40" typeName="INT_TO_STRING" executionOrderId="0">
<position x="561" y="412"/>
<inputVariables>
<variable formalParameter="IN">
<connectionPointIn>
<relPosition x="0" y="30"/>
<connection refLocalId="5" formalParameter="OUT">
<position x="561" y="442"/>
<position x="531" y="442"/>
</connection>
</connectionPointIn>
</variable>
</inputVariables>
<inOutVariables/>
<outputVariables>
<variable formalParameter="OUT">
<connectionPointOut>
<relPosition x="119" y="30"/>
</connectionPointOut>
</variable>
</outputVariables>
</block>
<block localId="10" width="106" height="40" typeName="BOOL_TO_INT" executionOrderId="0">
<position x="339" y="412"/>
<inputVariables>
<variable formalParameter="IN" edge="rising">
<connectionPointIn>
<relPosition x="0" y="30"/>
<connection refLocalId="3" formalParameter="OUT">
<position x="339" y="442"/>
<position x="314" y="442"/>
<position x="314" y="317"/>
<position x="300" y="317"/>
</connection>
</connectionPointIn>
</variable>
</inputVariables>
<inOutVariables/>
<outputVariables>
<variable formalParameter="OUT">
<connectionPointOut>
<relPosition x="106" y="30"/>
</connectionPointOut>
</variable>
</outputVariables>
</block>
<block localId="11" width="65" height="209" typeName="LOGGER" instanceName="LOGGER0" executionOrderId="0">
<position x="907" y="266"/>
<inputVariables>
<variable formalParameter="TRIG">
<connectionPointIn>
<relPosition x="0" y="51"/>
<connection refLocalId="3" formalParameter="OUT">
<position x="907" y="317"/>
<position x="300" y="317"/>
</connection>
</connectionPointIn>
</variable>
<variable formalParameter="MSG">
<connectionPointIn>
<relPosition x="0" y="114"/>
<connection refLocalId="8" formalParameter="OUT">
<position x="907" y="380"/>
<position x="794" y="380"/>
</connection>
</connectionPointIn>
</variable>
<variable formalParameter="LEVEL">
<connectionPointIn>
<relPosition x="0" y="177"/>
<connection refLocalId="12">
<position x="907" y="443"/>
<position x="893" y="443"/>
<position x="893" y="445"/>
<position x="879" y="445"/>
</connection>
</connectionPointIn>
</variable>
</inputVariables>
<inOutVariables/>
<outputVariables/>
</block>
<inVariable localId="12" height="30" width="79" executionOrderId="0" negated="false">
<position x="800" y="430"/>
<connectionPointOut>
<relPosition x="79" y="15"/>
</connectionPointOut>
<expression>lvl</expression>
</inVariable>
<block localId="14" typeName="TOF" instanceName="Timer" executionOrderId="0" height="98" width="47">
<position x="150" y="278"/>
<inputVariables>
<variable formalParameter="IN">
<connectionPointIn>
<relPosition x="0" y="39"/>
<connection refLocalId="4">
<position x="150" y="317"/>
<position x="133" y="317"/>
<position x="133" y="319"/>
<position x="117" y="319"/>
</connection>
</connectionPointIn>
</variable>
<variable formalParameter="PT">
<connectionPointIn>
<relPosition x="0" y="78"/>
<connection refLocalId="1">
<position x="150" y="356"/>
<position x="133" y="356"/>
<position x="133" y="359"/>
<position x="117" y="359"/>
</connection>
</connectionPointIn>
</variable>
</inputVariables>
<inOutVariables/>
<outputVariables>
<variable formalParameter="Q">
<connectionPointOut>
<relPosition x="47" y="39"/>
</connectionPointOut>
</variable>
<variable formalParameter="ET">
<connectionPointOut>
<relPosition x="47" y="78"/>
</connectionPointOut>
</variable>
</outputVariables>
</block>
<inVariable localId="1" executionOrderId="0" height="30" width="52" negated="false">
<position x="65" y="344"/>
<connectionPointOut>
<relPosition x="52" y="15"/>
</connectionPointOut>
<expression>T#3s</expression>
</inVariable>
<comment localId="15" height="238" width="675">
<position x="27" y="16"/>
<content>
<xhtml:p><![CDATA[This example shows logging functionality in Beremiz.
Here are shown two ways of logging:
- from IEC PLC program;
- from python extension.
In IEC PLC program every third second (beat) new message is generated and put in PLC log.
See function blocks below.
Every 15 seconds status of PLC program is put in PLC log from python extension.
For more information about logging from python look at 0.x: py_ext_0 implementation in project tree.
]]></xhtml:p>
</content>
</comment>
</FBD>
</body>
</pou>
</pous>
</types>
<instances>
<configurations>
<configuration name="config">
<resource name="resource1">
<task name="task0" priority="0" interval="T#100ms">
<pouInstance name="prg" typeName="program0"/>
</task>
</resource>
</configuration>
</configurations>
</instances>
</project>