beremiz

SVGHMI: Quicker update path for input widget when pressing on buttons, do not wait until data comes back, and simply update value text of the pressed widget. Updated PLC prog for more amimated value to display
<?xml version='1.0' encoding='utf-8'?>
<project xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.plcopen.org/xml/tc6_0201" xmlns:xhtml="http://www.w3.org/1999/xhtml" xsi:schemaLocation="http://www.plcopen.org/xml/tc6_0201">
<fileHeader companyName="beremiz" productName="beremiz" productVersion="1" creationDateTime="2008-06-24T18:44:00"/>
<contentHeader name="canopen_master" modificationDateTime="2018-09-26T13:31:52" language="en-US">
<coordinateInfo>
<fbd>
<scaling x="0" y="0"/>
</fbd>
<ld>
<scaling x="0" y="0"/>
</ld>
<sfc>
<scaling x="0" y="0"/>
</sfc>
</coordinateInfo>
</contentHeader>
<types>
<dataTypes/>
<pous>
<pou name="test_main" pouType="program">
<interface>
<localVars>
<variable name="PLC_OUT" address="%QW0.0.2.8193.0">
<type>
<INT/>
</type>
</variable>
<variable name="PLC_IN" address="%IW0.0.2.8192.0">
<type>
<INT/>
</type>
</variable>
</localVars>
</interface>
<body>
<FBD>
<outVariable localId="1" height="29" width="80" executionOrderId="0" negated="false">
<position x="362" y="139"/>
<connectionPointIn>
<relPosition x="0" y="14"/>
<connection refLocalId="4" formalParameter="OUT">
<position x="362" y="153"/>
<position x="299" y="153"/>
</connection>
</connectionPointIn>
<expression>PLC_OUT</expression>
</outVariable>
<inVariable localId="2" height="29" width="20">
<position x="100" y="115"/>
<connectionPointOut>
<relPosition x="20" y="14"/>
</connectionPointOut>
<expression>1</expression>
</inVariable>
<block localId="4" width="75" height="60" typeName="ADD">
<position x="224" y="123"/>
<inputVariables>
<variable formalParameter="IN1">
<connectionPointIn>
<relPosition x="0" y="30"/>
<connection refLocalId="2">
<position x="224" y="153"/>
<position x="183" y="153"/>
<position x="183" y="129"/>
<position x="120" y="129"/>
</connection>
</connectionPointIn>
</variable>
<variable formalParameter="IN2">
<connectionPointIn>
<relPosition x="0" y="50"/>
<connection refLocalId="5">
<position x="224" y="173"/>
<position x="199" y="173"/>
<position x="199" y="201"/>
<position x="174" y="201"/>
</connection>
</connectionPointIn>
</variable>
</inputVariables>
<inOutVariables/>
<outputVariables>
<variable formalParameter="OUT">
<connectionPointOut>
<relPosition x="75" y="30"/>
</connectionPointOut>
</variable>
</outputVariables>
</block>
<inVariable localId="5" height="29" width="70">
<position x="104" y="187"/>
<connectionPointOut>
<relPosition x="70" y="14"/>
</connectionPointOut>
<expression>PLC_IN</expression>
</inVariable>
</FBD>
</body>
</pou>
</pous>
</types>
<instances>
<configurations>
<configuration name="conf">
<resource name="res">
<task name="tache" interval="t#50ms" priority="0">
<pouInstance name="toto" typeName="test_main"/>
</task>
</resource>
</configuration>
</configurations>
</instances>
</project>