beremiz

Conform to pep8 and pylint :

2019-04-07, Edouard Tisserant
8fb5c6eddc72
Conform to pep8 and pylint :

pep8 version: 2.3.1
./ConfigTreeNode.py:130:49: E231 missing whitespace after ','
./editors/Viewer.py:643:24: E128 continuation line under-indented for visual indent
./editors/Viewer.py:670:12: E221 multiple spaces before operator
./editors/Viewer.py:671:13: E221 multiple spaces before operator
./editors/Viewer.py:2138:52: E203 whitespace before ':'
./editors/Viewer.py:2139:66: W291 trailing whitespace
./controls/VariablePanel.py:154:25: E231 missing whitespace after ','
./controls/LocationCellEditor.py:88:1: W293 blank line contains whitespace
./controls/LocationCellEditor.py:191:25: E221 multiple spaces before operator
./controls/LocationCellEditor.py:200:17: E128 continuation line under-indented for visual indent

pylint 1.8.3,
************* Module controls.LocationCellEditor
controls/LocationCellEditor.py:200: [C0330(bad-continuation), ] Wrong continued indentation (add 9 spaces).
_("Selected location is identical to previous one"))
^ |
************* Module controls.VariablePanel
controls/VariablePanel.py:154: [E1601(print-statement), VariableTable.SetValue] print statement used
************* Module editors.Viewer
editors/Viewer.py:643: [C0330(bad-continuation), ] Wrong continued indentation (add 1 space).
self.GetAddMenuCallBack(self.AddNewComment))
^|
editors/Viewer.py:598: [W0612(unused-variable), Viewer.AddDivergenceMenuItems] Unused variable 'add_branch'
editors/Viewer.py:1655: [E0602(undefined-variable), Viewer.PopupConnectionMenu] Undefined variable 'variable_type'
editors/Viewer.py:1649: [W0612(unused-variable), Viewer.PopupConnectionMenu] Unused variable 'connection_type'
************* Module connectors.PYRO.PSK_Adapter
<?xml version='1.0' encoding='utf-8'?>
<PyFile xmlns:xhtml="http://www.w3.org/1999/xhtml">
<variables>
<variable name="Test_Python_Var" type="INT" initial="4"/>
<variable name="Second_Python_Var" type="INT" initial="5"/>
</variables>
<globals>
<xhtml:p><![CDATA[
import time,sys,ctypes
Python_to_C_Call = PLCBinary.Python_to_C_Call
Python_to_C_Call.restype = ctypes.c_int
Python_to_C_Call.argtypes = [ctypes.c_int, ctypes.POINTER(ctypes.c_int)]
def MyPythonFunc(arg):
i = ctypes.c_int()
if(Python_to_C_Call(arg, i)):
res = i.value
print "toC:", arg, "from C:", res, "FBID:", FBID
else:
print "Failed Python_to_C_Call failed"
res = None
print "Python read PLC global :",PLCGlobals.Test_Python_Var
PLCGlobals.Second_Python_Var = 789
sys.stdout.flush()
return res
async_error_test_code = """
def badaboom():
tuple()[0]
import wx
def badaboomwx():
wx.CallAfter(badaboom)
from threading import Timer
a = Timer(3, badaboom)
a.start()
b = Timer(6, badaboomwx)
b.start()
"""
]]></xhtml:p>
</globals>
<init>
<xhtml:p><![CDATA[
global x, y
x = 2
y = 5
print "py_runtime init:", x, ",", y
]]></xhtml:p>
</init>
<cleanup>
<xhtml:p><![CDATA[
print "py_runtime cleanup"
]]></xhtml:p>
</cleanup>
<start>
<xhtml:p><![CDATA[
global x, y
print "py_runtime start", x * x + y * y
]]></xhtml:p>
</start>
<stop>
<xhtml:p><![CDATA[
print "py_runtime stop"
]]></xhtml:p>
</stop>
</PyFile>