beremiz

cleanup pyc files between running pytest

2018-10-05, Andrey Skvortsov
925adaa2cd5c
cleanup pyc files between running pytest

this is need to avoid problem sometimes tests are run inside docker
container and sometimes local.

Traceback (most recent call last):
File "/usr/lib/python2.7/dist-packages/_pytest/config/__init__.py", line 409, in _importconftest
mod = conftestpath.pyimport()
File "/usr/lib/python2.7/dist-packages/py/_path/local.py", line 686, in pyimport
raise self.ImportMismatchError(modname, modfile, self)
ImportMismatchError: ('conftest', '/beremiz/tests/tools/conftest.py', local('/home/developer/beremiz/tests/tools/conftest.py'))
ERROR: could not load /home/developer/beremiz/tests/tools/conftest.py
<?xml version="1.0" encoding="UTF-8"?>
<project xmlns="http://www.plcopen.org/xml/tc6.xsd"
xsi:schemaLocation="http://www.plcopen.org/xml/tc6.xsd"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xmlns:xhtml="http://www.w3.org/1999/xhtml">
<fileHeader companyName="Unknown"
productName="Unnamed"
productVersion="1"
creationDateTime="2013-01-29T14:01:00"/>
<contentHeader name="Unnamed"
modificationDateTime="2013-02-26T15:59:13">
<coordinateInfo>
<fbd>
<scaling x="0" y="0"/>
</fbd>
<ld>
<scaling x="0" y="0"/>
</ld>
<sfc>
<scaling x="0" y="0"/>
</sfc>
</coordinateInfo>
</contentHeader>
<types>
<dataTypes>
<dataType name="LOGLEVEL">
<baseType>
<enum>
<values>
<value name="CRITICAL"/>
<value name="WARNING"/>
<value name="INFO"/>
<value name="DEBUG"/>
</values>
</enum>
</baseType>
<initialValue>
<simpleValue value="INFO"/>
</initialValue>
</dataType>
</dataTypes>
<pous>
<pou name="LOGGER" pouType="functionBlock">
<interface>
<inputVars>
<variable name="TRIG">
<type>
<BOOL/>
</type>
</variable>
<variable name="MSG">
<type>
<string/>
</type>
</variable>
<variable name="LEVEL">
<type>
<derived name="LOGLEVEL"/>
</type>
<initialValue>
<simpleValue value="INFO"/>
</initialValue>
</variable>
</inputVars>
<localVars>
<variable name="TRIG0">
<type>
<BOOL/>
</type>
</variable>
</localVars>
</interface>
<body>
<ST>
<![CDATA[IF TRIG AND NOT TRIG0 THEN
{{
LogMessage(GetFbVar(LEVEL),(char*)GetFbVar(MSG, .body),GetFbVar(MSG, .len));
}}
END_IF;
TRIG0:=TRIG;
]]>
</ST>
</body>
</pou>
</pous>
</types>
<instances>
<configurations/>
</instances>
</project>