beremiz

SVGHMI: Fixed problems happening when value is higher than maximum or lower than minimum in Input widget. "max" and "min" string was getting into keypad text field, was not diplayed systematically, and was staying forever sometime.
<?xml version='1.0' encoding='utf-8'?>
<project xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.plcopen.org/xml/tc6_0201" xmlns:xhtml="http://www.w3.org/1999/xhtml" xsi:schemaLocation="http://www.plcopen.org/xml/tc6_0201">
<fileHeader companyName="beremiz" productName="beremiz" productVersion="1" creationDateTime="2008-06-24T18:44:00"/>
<contentHeader name="canopen_master" modificationDateTime="2018-09-26T13:31:52" language="en-US">
<coordinateInfo>
<fbd>
<scaling x="0" y="0"/>
</fbd>
<ld>
<scaling x="0" y="0"/>
</ld>
<sfc>
<scaling x="0" y="0"/>
</sfc>
</coordinateInfo>
</contentHeader>
<types>
<dataTypes/>
<pous>
<pou name="test_main" pouType="program">
<interface>
<localVars>
<variable name="PLC_OUT" address="%QW0.0.2.8193.0">
<type>
<INT/>
</type>
</variable>
<variable name="PLC_IN" address="%IW0.0.2.8192.0">
<type>
<INT/>
</type>
</variable>
</localVars>
</interface>
<body>
<FBD>
<outVariable localId="1" height="29" width="80" executionOrderId="0" negated="false">
<position x="362" y="139"/>
<connectionPointIn>
<relPosition x="0" y="14"/>
<connection refLocalId="4" formalParameter="OUT">
<position x="362" y="153"/>
<position x="299" y="153"/>
</connection>
</connectionPointIn>
<expression>PLC_OUT</expression>
</outVariable>
<inVariable localId="2" height="29" width="20">
<position x="100" y="115"/>
<connectionPointOut>
<relPosition x="20" y="14"/>
</connectionPointOut>
<expression>1</expression>
</inVariable>
<block localId="4" width="75" height="60" typeName="ADD">
<position x="224" y="123"/>
<inputVariables>
<variable formalParameter="IN1">
<connectionPointIn>
<relPosition x="0" y="30"/>
<connection refLocalId="2">
<position x="224" y="153"/>
<position x="183" y="153"/>
<position x="183" y="129"/>
<position x="120" y="129"/>
</connection>
</connectionPointIn>
</variable>
<variable formalParameter="IN2">
<connectionPointIn>
<relPosition x="0" y="50"/>
<connection refLocalId="5">
<position x="224" y="173"/>
<position x="199" y="173"/>
<position x="199" y="201"/>
<position x="174" y="201"/>
</connection>
</connectionPointIn>
</variable>
</inputVariables>
<inOutVariables/>
<outputVariables>
<variable formalParameter="OUT">
<connectionPointOut>
<relPosition x="75" y="30"/>
</connectionPointOut>
</variable>
</outputVariables>
</block>
<inVariable localId="5" height="29" width="70">
<position x="104" y="187"/>
<connectionPointOut>
<relPosition x="70" y="14"/>
</connectionPointOut>
<expression>PLC_IN</expression>
</inVariable>
</FBD>
</body>
</pou>
</pous>
</types>
<instances>
<configurations>
<configuration name="conf">
<resource name="res">
<task name="tache" interval="t#50ms" priority="0">
<pouInstance name="toto" typeName="test_main"/>
</task>
</resource>
</configuration>
</configurations>
</instances>
</project>