beremiz

IDE: Optimization of modification events processing in text editors.

Too many modifications types where registered, and then too many events were fired.
Also, in case of uninterrupted sequence of events, updates to the model is deferred to the end of that sequence (wx.Callafter).
<?xml version='1.0' encoding='utf-8'?>
<project xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.plcopen.org/xml/tc6_0201" xmlns:xhtml="http://www.w3.org/1999/xhtml" xsi:schemaLocation="http://www.plcopen.org/xml/tc6_0201">
<fileHeader companyName="beremiz" productName="beremiz" productVersion="1" creationDateTime="2008-06-24T18:44:00"/>
<contentHeader name="canopen_master" modificationDateTime="2018-09-26T13:31:52" language="en-US">
<coordinateInfo>
<fbd>
<scaling x="0" y="0"/>
</fbd>
<ld>
<scaling x="0" y="0"/>
</ld>
<sfc>
<scaling x="0" y="0"/>
</sfc>
</coordinateInfo>
</contentHeader>
<types>
<dataTypes/>
<pous>
<pou name="test_main" pouType="program">
<interface>
<localVars>
<variable name="PLC_OUT" address="%QW0.0.2.8193.0">
<type>
<INT/>
</type>
</variable>
<variable name="PLC_IN" address="%IW0.0.2.8192.0">
<type>
<INT/>
</type>
</variable>
</localVars>
</interface>
<body>
<FBD>
<outVariable localId="1" height="29" width="80" executionOrderId="0" negated="false">
<position x="362" y="139"/>
<connectionPointIn>
<relPosition x="0" y="14"/>
<connection refLocalId="4" formalParameter="OUT">
<position x="362" y="153"/>
<position x="299" y="153"/>
</connection>
</connectionPointIn>
<expression>PLC_OUT</expression>
</outVariable>
<inVariable localId="2" height="29" width="20">
<position x="100" y="115"/>
<connectionPointOut>
<relPosition x="20" y="14"/>
</connectionPointOut>
<expression>1</expression>
</inVariable>
<block localId="4" width="75" height="60" typeName="ADD">
<position x="224" y="123"/>
<inputVariables>
<variable formalParameter="IN1">
<connectionPointIn>
<relPosition x="0" y="30"/>
<connection refLocalId="2">
<position x="224" y="153"/>
<position x="183" y="153"/>
<position x="183" y="129"/>
<position x="120" y="129"/>
</connection>
</connectionPointIn>
</variable>
<variable formalParameter="IN2">
<connectionPointIn>
<relPosition x="0" y="50"/>
<connection refLocalId="5">
<position x="224" y="173"/>
<position x="199" y="173"/>
<position x="199" y="201"/>
<position x="174" y="201"/>
</connection>
</connectionPointIn>
</variable>
</inputVariables>
<inOutVariables/>
<outputVariables>
<variable formalParameter="OUT">
<connectionPointOut>
<relPosition x="75" y="30"/>
</connectionPointOut>
</variable>
</outputVariables>
</block>
<inVariable localId="5" height="29" width="70">
<position x="104" y="187"/>
<connectionPointOut>
<relPosition x="70" y="14"/>
</connectionPointOut>
<expression>PLC_IN</expression>
</inVariable>
</FBD>
</body>
</pou>
</pous>
</types>
<instances>
<configurations>
<configuration name="conf">
<resource name="res">
<task name="tache" interval="t#50ms" priority="0">
<pouInstance name="toto" typeName="test_main"/>
</task>
</resource>
</configuration>
</configurations>
</instances>
</project>