beremiz

c9915bc620cd
Fix wrong code generation if EN/ENO are used in FBD/LD/SFC

This problem appears for example here

--------
------- | MOVE |
| MOVE1 |------|EN ENO|
------- | |
| |
------- | | -----------
| 23 |------|IN OUT|---| LocalVar0 |
------- -------- -----------


--------
------- | MOVE |
| MOVE2 |------|EN ENO|
------- | |
| |
------- | | -----------
| 15 |------|IN OUT|---| LocalVar0 |
------- -------- -----------

Before wrong code was generated for this case:

MOVE6_OUT := MOVE(EN := move1, IN := 23, ENO => MOVE6_ENO);
LocalVar0 := MOVE6_OUT;
MOVE4_OUT := MOVE(EN := move2, IN := 15, ENO => MOVE4_ENO);
LocalVar0 := MOVE4_OUT;

With this patch now following code is generated:

MOVE6_OUT := MOVE(EN := move1, IN := 23, ENO => MOVE6_ENO);
IF MOVE6_ENO THEN
LocalVar0 := MOVE6_OUT;
END_IF;
MOVE4_OUT := MOVE(EN := move2, IN := 15, ENO => MOVE4_ENO);
IF MOVE4_ENO THEN
LocalVar0 := MOVE4_OUT;
END_IF;


See discussion here:
https://sourceforge.net/p/beremiz/mailman/message/36378805/
<?xml version='1.0' encoding='utf-8'?>
<CFile xmlns:xhtml="http://www.w3.org/1999/xhtml">
<includes>
<xhtml:p><![CDATA[
]]></xhtml:p>
</includes>
<variables>
<variable name="TestInput" type="SINT" initial="0"/>
<variable name="TestOutput" type="SINT"/>
</variables>
<globals>
<xhtml:p><![CDATA[
volatile long Lock=0;
volatile char PtoC=1,CtoP=2;
extern long AtomicCompareExchange(long*,long, long);
extern char *PLC_ID;
int Simple_C_Call(int val){
return val+1;
}
int Python_to_C_Call(char toC, char *fromC){
/* Code called by python should never touch to
variables modified by PLC thread directly
AtomicCompareExchange comes from
beremiz' runtime implementation */
int res = 0;
if(!AtomicCompareExchange((long*)&Lock, 0, 1)){
PtoC=toC;
*fromC=CtoP;
AtomicCompareExchange((long*)&Lock, 1, 0);
res=1;
}
printf("C code called by Python: toC %d fromC %d\n",toC,*fromC);
printf("PLC_ID id %s\n",PLC_ID);
return res;
}
int PLC_C_Call(char fromPLC, char *toPLC){
/* PLC also have to be realy carefull not to
conflict with asynchronous python access */
if(!AtomicCompareExchange((long*)&Lock, 0, 1)){
CtoP = fromPLC;
*toPLC = PtoC;
AtomicCompareExchange((long*)&Lock, 1, 0);
return 1;
}
return 0;
}
]]></xhtml:p>
</globals>
<initFunction>
<xhtml:p><![CDATA[
]]></xhtml:p>
</initFunction>
<cleanUpFunction>
<xhtml:p><![CDATA[
]]></xhtml:p>
</cleanUpFunction>
<retrieveFunction>
<xhtml:p><![CDATA[
]]></xhtml:p>
</retrieveFunction>
<publishFunction>
<xhtml:p><![CDATA[
if(!AtomicCompareExchange((long*)&Lock, 0, 1)){
TestInput = CtoP + PtoC + TestOutput;
AtomicCompareExchange((long*)&Lock, 1, 0);
}
]]></xhtml:p>
</publishFunction>
</CFile>