e10a1095f577
Fixed repetitive freezing of IDE when connection drops.
when connection lost error was beeing displayed, the involved wxYield
was calling pending plc status periodic update, itself trying to use connector.
At that time connector is still not destroyed and connection
is attempted again when calling GetPLCStatus.
=> Hack : Ensure connector is destroyed before reporting error.
<?xml version='1.0' encoding='utf-8'?>
<PyFile xmlns:xhtml="http://www.w3.org/1999/xhtml" xmlns:xsd="http://www.w3.org/2001/XMLSchema">
<variables/>
<globals>
<xhtml:p><![CDATA[import threading, time
MyT = None
Stop = False
def StartLog():
global MyT
MyT=threading.Thread(target = DoLog)
MyT.start()
def DoLog():
global Stop
while not Stop:
PLCObject.LogMessage("Python side Logging (PLC is %s)"%PLCObject.PLCStatus)
time.sleep(0.3)
def StopLog():
global MyT,Stop
Stop=True
_runtime_init.append(StartLog)
_runtime_cleanup.append(StopLog)
]]></xhtml:p>
</globals>
<init>
<xhtml:p><![CDATA[]]></xhtml:p>
</init>
<cleanup>
<xhtml:p><![CDATA[]]></xhtml:p>
</cleanup>
<start>
<xhtml:p><![CDATA[]]></xhtml:p>
</start>
<stop>
<xhtml:p><![CDATA[]]></xhtml:p>
</stop>