Modbus: fix test: add missing filles and add Modbus source+build in GH CI
--- a/.github/workflows/run_tests_in_docker.yml Thu Apr 04 17:31:49 2024 +0200
+++ b/.github/workflows/run_tests_in_docker.yml Thu Apr 04 17:58:21 2024 +0200
@@ -28,6 +28,12 @@
+ - uses: actions/checkout@v3 + repository: beremiz/Modbus + ref: 4d7d67a8e911d744165709c20a254b5cb924ec71 - name: Restore cached docker image
uses: actions/cache/restore@v3
--- /dev/null Thu Jan 01 00:00:00 1970 +0000
+++ b/tests/projects/modbus_test_tcp/modbus_0@modbus/ModbusTCPclient_0@ModbusTCPclient/ModbusRequest_0@ModbusRequest/baseconfnode.xml Thu Apr 04 17:58:21 2024 +0200
@@ -0,0 +1,2 @@
+<?xml version='1.0' encoding='utf-8'?> +<BaseParams xmlns:xsd="http://www.w3.org/2001/XMLSchema" IEC_Channel="0" Name="ModbusRequest_0"/> --- /dev/null Thu Jan 01 00:00:00 1970 +0000
+++ b/tests/projects/modbus_test_tcp/modbus_0@modbus/ModbusTCPclient_0@ModbusTCPclient/ModbusRequest_0@ModbusRequest/confnode.xml Thu Apr 04 17:58:21 2024 +0200
@@ -0,0 +1,2 @@
+<?xml version='1.0' encoding='utf-8'?> +<ModbusRequest xmlns:xsd="http://www.w3.org/2001/XMLSchema" Function="16 - Write Multiple Registers" SlaveID="0"/> --- /dev/null Thu Jan 01 00:00:00 1970 +0000
+++ b/tests/projects/modbus_test_tcp/modbus_0@modbus/ModbusTCPclient_0@ModbusTCPclient/ModbusRequest_1@ModbusRequest/baseconfnode.xml Thu Apr 04 17:58:21 2024 +0200
@@ -0,0 +1,2 @@
+<?xml version='1.0' encoding='utf-8'?> +<BaseParams xmlns:xsd="http://www.w3.org/2001/XMLSchema" IEC_Channel="1" Name="ModbusRequest_1"/> --- /dev/null Thu Jan 01 00:00:00 1970 +0000
+++ b/tests/projects/modbus_test_tcp/modbus_0@modbus/ModbusTCPclient_0@ModbusTCPclient/ModbusRequest_1@ModbusRequest/confnode.xml Thu Apr 04 17:58:21 2024 +0200
@@ -0,0 +1,2 @@
+<?xml version='1.0' encoding='utf-8'?> +<ModbusRequest xmlns:xsd="http://www.w3.org/2001/XMLSchema" Function="04 - Read Input Registers" SlaveID="0" Start_Address="0"/> --- /dev/null Thu Jan 01 00:00:00 1970 +0000
+++ b/tests/projects/modbus_test_tcp/modbus_0@modbus/ModbusTCPclient_0@ModbusTCPclient/baseconfnode.xml Thu Apr 04 17:58:21 2024 +0200
@@ -0,0 +1,2 @@
+<?xml version='1.0' encoding='utf-8'?> +<BaseParams xmlns:xsd="http://www.w3.org/2001/XMLSchema" IEC_Channel="0" Name="ModbusTCPclient_0"/> --- /dev/null Thu Jan 01 00:00:00 1970 +0000
+++ b/tests/projects/modbus_test_tcp/modbus_0@modbus/ModbusTCPclient_0@ModbusTCPclient/confnode.xml Thu Apr 04 17:58:21 2024 +0200
@@ -0,0 +1,2 @@
+<?xml version='1.0' encoding='utf-8'?> +<ModbusTCPclient xmlns:xsd="http://www.w3.org/2001/XMLSchema" Remote_Port_Number="1502" Configuration_Name="Modbus TCP Client 0.0"/> --- /dev/null Thu Jan 01 00:00:00 1970 +0000
+++ b/tests/projects/modbus_test_tcp/modbus_0@modbus/ModbusTCPserver_0@ModbusTCPserver/HoldingRegs@MemoryArea/baseconfnode.xml Thu Apr 04 17:58:21 2024 +0200
@@ -0,0 +1,2 @@
+<?xml version='1.0' encoding='utf-8'?> +<BaseParams xmlns:xsd="http://www.w3.org/2001/XMLSchema" IEC_Channel="0" Name="HoldingRegs"/> --- /dev/null Thu Jan 01 00:00:00 1970 +0000
+++ b/tests/projects/modbus_test_tcp/modbus_0@modbus/ModbusTCPserver_0@ModbusTCPserver/HoldingRegs@MemoryArea/confnode.xml Thu Apr 04 17:58:21 2024 +0200
@@ -0,0 +1,2 @@
+<?xml version='1.0' encoding='utf-8'?> +<MemoryArea xmlns:xsd="http://www.w3.org/2001/XMLSchema" MemoryAreaType="03 - Holding Registers" Nr_of_Channels="1"/> --- /dev/null Thu Jan 01 00:00:00 1970 +0000
+++ b/tests/projects/modbus_test_tcp/modbus_0@modbus/ModbusTCPserver_0@ModbusTCPserver/InputRegs@MemoryArea/baseconfnode.xml Thu Apr 04 17:58:21 2024 +0200
@@ -0,0 +1,2 @@
+<?xml version='1.0' encoding='utf-8'?> +<BaseParams xmlns:xsd="http://www.w3.org/2001/XMLSchema" IEC_Channel="1" Name="InputRegs"/> --- /dev/null Thu Jan 01 00:00:00 1970 +0000
+++ b/tests/projects/modbus_test_tcp/modbus_0@modbus/ModbusTCPserver_0@ModbusTCPserver/InputRegs@MemoryArea/confnode.xml Thu Apr 04 17:58:21 2024 +0200
@@ -0,0 +1,2 @@
+<?xml version='1.0' encoding='utf-8'?> +<MemoryArea xmlns:xsd="http://www.w3.org/2001/XMLSchema" MemoryAreaType="04 - Input Registers"/> --- /dev/null Thu Jan 01 00:00:00 1970 +0000
+++ b/tests/projects/modbus_test_tcp/modbus_0@modbus/ModbusTCPserver_0@ModbusTCPserver/baseconfnode.xml Thu Apr 04 17:58:21 2024 +0200
@@ -0,0 +1,2 @@
+<?xml version='1.0' encoding='utf-8'?> +<BaseParams xmlns:xsd="http://www.w3.org/2001/XMLSchema" IEC_Channel="1" Name="ModbusTCPserver_0"/> --- /dev/null Thu Jan 01 00:00:00 1970 +0000
+++ b/tests/projects/modbus_test_tcp/modbus_0@modbus/ModbusTCPserver_0@ModbusTCPserver/confnode.xml Thu Apr 04 17:58:21 2024 +0200
@@ -0,0 +1,2 @@
+<?xml version='1.0' encoding='utf-8'?> +<ModbusServerNode xmlns:xsd="http://www.w3.org/2001/XMLSchema" Local_Port_Number="1502" Local_IP_Address="127.0.0.1" Configuration_Name="Modbus TCP Server 0.1"/>