--- a/Beremiz_service.py Wed Apr 24 12:24:12 2013 +0900
+++ b/Beremiz_service.py Wed Apr 24 15:44:46 2013 +0900
@@ -425,8 +425,8 @@
def default_evaluator(tocall, *args, **kwargs):
res=(tocall(*args,**kwargs), None)
+ res=(None, sys.exc_info()) --- a/runtime/PLCObject.py Wed Apr 24 12:24:12 2013 +0900
+++ b/runtime/PLCObject.py Wed Apr 24 15:44:46 2013 +0900
@@ -243,13 +243,10 @@
Calls init, start, stop or cleanup method provided by
runtime python files, loaded when new PLC uploaded
- for method in self.python_runtime_vars.get("_runtime_%s"%methodname, []):
- res,exp = self.evaluator(method)
- if exp is not None: raise(exp)
- self.LogMessage(0,traceback.format_exc())
+ for method in self.python_runtime_vars.get("_runtime_%s"%methodname, []): + res,exp = self.evaluator(method) + self.LogMessage(0,traceback.format_exception(*exp)) def PythonRuntimeInit(self):
MethodNames = ["init", "start", "stop", "cleanup"]
@@ -312,7 +309,7 @@
compile_cache[FBID]=(cmd,AST)
result,exp = self.evaluator(eval,cmd,self.python_runtime_vars)
self.python_runtime_vars["FBID"]=None