lpcmanager

Parents 1d7bf86274cc
Children 70b165fd1a0f
#2585 removed useless PythonFileCTNMixin CTNGenerate_C override, after in depth compare to the original - why such bloat ?
  • +0 -216
    LPCManager.py
  • --- a/LPCManager.py Tue Feb 06 15:33:44 2018 +0100
    +++ b/LPCManager.py Tue Feb 06 16:02:40 2018 +0100
    @@ -106,222 +106,6 @@
    # Add LPCmanager's image folder to searched ones.
    AddBitmapFolder(os.path.join(_lpcmanager_path, "images"))
    -
    -# from controls.LogViewer import LogViewer
    -from VariableExporter import VariableWriter
    -from PLCControler import PLCControler, ITEMS_UNEDITABLE, ITEM_POU
    -from wx.lib.scrolledpanel import ScrolledPanel
    -from types import MethodType
    -from IDEFrame import IDEFrame
    -from dialogs import SearchInProjectDialog
    -from controls import TextCtrlAutoComplete
    -from py_ext import PythonFileCTNMixin
    -from plcopen.structures import TestIdentifier, IDENTIFIER_MODEL
    -
    -def CTNGenerate_C(self, buildpath, locations):
    - # location string for that CTN
    - location_str = "_".join(map(lambda x: str(x),
    - self.GetCurrentLocation()))
    - configname = self.GetCTRoot().GetProjectConfigNames()[0]
    -
    - pyextname = self.CTNName()
    - varinfos = map(lambda variable: {
    - "name": variable.getname(),
    - "desc": repr(variable.getdesc()),
    - "onchangecode": '"' + variable.getonchange() + \
    - "('" + variable.getname() + "')\"" \
    - if variable.getonchange() else '""',
    - "onchange": repr(variable.getonchange()) \
    - if variable.getonchange() else None,
    - "opts": repr(variable.getopts()),
    - "configname": configname.upper(),
    - "uppername": variable.getname().upper(),
    - "IECtype": variable.gettype(),
    - "initial": repr(variable.getinitial()),
    - "pyextname": pyextname},
    - self.CodeFile.variables.variable)
    - # python side PLC global variables access stub
    - globalstubs = "\n".join(["""\
    -_%(name)s_ctype, _%(name)s_unpack, _%(name)s_pack = \\
    - TypeTranslator["%(IECtype)s"]
    -_PySafeGetPLCGlob_%(name)s = PLCBinary.__SafeGetPLCGlob_%(name)s
    -_PySafeGetPLCGlob_%(name)s.restype = None
    -_PySafeGetPLCGlob_%(name)s.argtypes = [ctypes.POINTER(_%(name)s_ctype)]
    -_PySafeSetPLCGlob_%(name)s = PLCBinary.__SafeSetPLCGlob_%(name)s
    -_PySafeSetPLCGlob_%(name)s.restype = None
    -_PySafeSetPLCGlob_%(name)s.argtypes = [ctypes.POINTER(_%(name)s_ctype)]
    -_%(pyextname)sGlobalsDesc.append((
    - "%(name)s",
    - "%(IECtype)s",
    - %(initial)s,
    - %(desc)s,
    - %(onchange)s,
    - %(opts)s))
    -""" % varinfo
    - for varinfo in varinfos])
    -
    - # Runtime calls (start, stop, init, and cleanup)
    - rtcalls = ""
    - for section in self.SECTIONS_NAMES:
    - if section != "globals":
    - rtcalls += "def _runtime_%s_%s():\n" % (location_str, section)
    - sectiontext = self.GetSection(section).strip()
    - if sectiontext:
    - rtcalls += ' ' + \
    - sectiontext.replace('\n', '\n ') + "\n\n"
    - else:
    - rtcalls += " pass\n\n"
    -
    - globalsection = self.GetSection("globals")
    -
    - PyFileContent = """\
    -#!/usr/bin/env python
    -# -*- coding: utf-8 -*-
    -## Code generated by Beremiz python mixin confnode
    -##
    -
    -## Code for PLC global variable access
    -from targets.typemapping import TypeTranslator
    -import ctypes
    -_%(pyextname)sGlobalsDesc = []
    -__ext_name__ = "%(pyextname)s"
    -PLCGlobalsDesc.append(( "%(pyextname)s" , _%(pyextname)sGlobalsDesc ))
    -%(globalstubs)s
    -
    -## User code in "global" scope
    -%(globalsection)s
    -
    -## Beremiz python runtime calls
    -%(rtcalls)s
    -
    -del __ext_name__
    -
    -""" % locals()
    -
    - # write generated content to python file
    - runtimefile_path = os.path.join(buildpath,
    - "runtime_%s.py" % location_str)
    - runtimefile = open(runtimefile_path, 'w')
    - runtimefile.write(PyFileContent.encode('utf-8'))
    - runtimefile.close()
    -
    - # C code for safe global variables access
    -
    - vardecfmt = """\
    -extern __IEC_%(IECtype)s_t %(configname)s__%(uppername)s;
    -IEC_%(IECtype)s __%(name)s_rbuffer = __INIT_%(IECtype)s;
    -IEC_%(IECtype)s __%(name)s_wbuffer;
    -long __%(name)s_rlock = 0;
    -long __%(name)s_wlock = 0;
    -int __%(name)s_wbuffer_written = 0;
    -void __SafeGetPLCGlob_%(name)s(IEC_%(IECtype)s *pvalue){
    - while(AtomicCompareExchange(&__%(name)s_rlock, 0, 1));
    - *pvalue = __%(name)s_rbuffer;
    - AtomicCompareExchange((long*)&__%(name)s_rlock, 1, 0);
    -}
    -void __SafeSetPLCGlob_%(name)s(IEC_%(IECtype)s *value){
    - while(AtomicCompareExchange(&__%(name)s_wlock, 0, 1));
    - __%(name)s_wbuffer = *value;
    - __%(name)s_wbuffer_written = 1;
    - AtomicCompareExchange((long*)&__%(name)s_wlock, 1, 0);
    -}
    -
    -"""
    -
    - vardeconchangefmt = """\
    -PYTHON_POLL* __%(name)s_notifier;
    -"""
    -
    - varretfmt = """\
    - if(!AtomicCompareExchange(&__%(name)s_wlock, 0, 1)){
    - if(__%(name)s_wbuffer_written == 1){
    - %(configname)s__%(uppername)s.value = __%(name)s_wbuffer;
    - __%(name)s_wbuffer_written = 0;
    - }
    - AtomicCompareExchange((long*)&__%(name)s_wlock, 1, 0);
    - }
    -"""
    - varpubfmt = """\
    - if(!AtomicCompareExchange(&__%(name)s_rlock, 0, 1)){
    - __%(name)s_rbuffer = __GET_VAR(%(configname)s__%(uppername)s);
    - AtomicCompareExchange((long*)&__%(name)s_rlock, 1, 0);
    - }
    -"""
    -
    - varpubonchangefmt = """\
    - if(!AtomicCompareExchange(&__%(name)s_rlock, 0, 1)){
    - IEC_%(IECtype)s tmp = __GET_VAR(%(configname)s__%(uppername)s);
    - if(__%(name)s_rbuffer != tmp){
    - __%(name)s_rbuffer = %(configname)s__%(uppername)s.value;
    - PYTHON_POLL_body__(__%(name)s_notifier);
    - }
    - AtomicCompareExchange((long*)&__%(name)s_rlock, 1, 0);
    - }
    -"""
    - varinitonchangefmt = """\
    - __%(name)s_notifier = __GET_GLOBAL_ON%(uppername)sCHANGE();
    - __SET_VAR(__%(name)s_notifier->,TRIG,,__BOOL_LITERAL(TRUE));
    - __SET_VAR(__%(name)s_notifier->,CODE,,__STRING_LITERAL(%(onchangelen)d,%(onchangecode)s));
    -"""
    - vardec = "\n".join([(vardecfmt + vardeconchangefmt
    - if varinfo["onchange"] else vardecfmt) % varinfo
    - for varinfo in varinfos])
    - varret = "\n".join([varretfmt % varinfo for varinfo in varinfos])
    - varpub = "\n".join([(varpubonchangefmt if varinfo["onchange"] else
    - varpubfmt) % varinfo
    - for varinfo in varinfos])
    - varinit = "\n".join([varinitonchangefmt % dict(
    - onchangelen=len(varinfo["onchangecode"]), **varinfo)
    - for varinfo in varinfos if varinfo["onchange"]])
    -
    - # TODO : use config name obtained from model instead of default
    - # "config.h". User cannot change config name, but project imported
    - # or created in older beremiz vesion could use different name.
    - PyCFileContent = """\
    -/*
    - * Code generated by Beremiz py_ext confnode
    - * for safe global variables access
    - */
    -#include "iec_types_all.h"
    -#include "POUS.h"
    -#include "config.h"
    -#include "beremiz.h"
    -
    -/* User variables reference */
    -%(vardec)s
    -
    -/* Beremiz confnode functions */
    -int __init_%(location_str)s(int argc,char **argv){
    -%(varinit)s
    - return 0;
    -}
    -
    -void __cleanup_%(location_str)s(void){
    -}
    -
    -void __retrieve_%(location_str)s(void){
    -%(varret)s
    -}
    -
    -void __publish_%(location_str)s(void){
    -%(varpub)s
    -}
    -""" % locals()
    -
    - Gen_PyCfile_path = os.path.join(buildpath, "PyCFile_%s.c" % location_str)
    - pycfile = open(Gen_PyCfile_path, 'w')
    - pycfile.write(PyCFileContent)
    - pycfile.close()
    -
    - matiec_CFLAGS = '"-I%s"' % os.path.abspath(
    - self.GetCTRoot().GetIECLibPath())
    -
    - return ([(Gen_PyCfile_path, matiec_CFLAGS)],
    - "",
    - True,
    - ("runtime_%s.py" % location_str, file(runtimefile_path, "rb")))
    -PythonFileCTNMixin.CTNGenerate_C = CTNGenerate_C
    -
    if __name__ == '__main__':